Product Description:

EO Ethylene Oxide Indicator Label - Storage Methods and Precautions The ethylene oxide indicator label only provides information on whether the sterilized items have been subjected to ethylene oxide sterilization, and does not reflect the degree and effectiveness of disinfection and sterilization of the items. This product is not suitable for use inside infusion bottles, tubes, or barrels. This product should not be directly in contact with water, nor should the indicator card be placed directly on surfaces made of metal or glass that are prone to condensation. The product should be stored at room temperature between 15°C and 30°C, with a relative humidity of 50%, and must be kept dry. The product should be protected from light (including sunlight, fluorescent lights, and ultraviolet disinfection lights), moisture, and must not be damp; The product should be prohibited from coming into contact with corrosive gases such as acids and alkalis, and should not be stored together with contaminated or toxic chemicals to avoid affecting the color-changing efficacy of the indicator. If any change in color of the product's indicator mark is observed, do not use it. This product can only be used for chemical monitoring of ethylene oxide sterilization and cannot be used for pressure steam or dry heat sterilization monitoring. The expiration date for the ethylene oxide sterilization indicator label is six months from the production date. EO Ethylene Oxide Indicator Label - Instructions for Use 1. Remove the ethylene oxide sterilization indicator label from the liner paper, place it directly on the surface of the package of the item to be sterilized, and press lightly on the label to enhance its sealing effect. Then place the package in an ethylene oxide sterilization chamber for sterilization treatment. 2. After the sterilization process is complete, remove the package and observe the color change of the indicator label. If the label changes from red to blue, it indicates that the package has undergone sterilization; if there is no change in color, it means the package has not been sterilized.

Inquiry:

CATEGORIES

CONTACT US

Contact: Mr. Ma

Phone: +86-18144382473

Tel: +86-18144382473

Email: mzx@dowsam.com

Add: No. 1238, Hezuo Road, High-tech West District, Chengdu City, Sichuan Provinc

Leave a message

 
Top